Evaluation of HER2/neu Status by Immunohistochemistry Using Computer-Based Image Analysis and Correlation With Gene Amplification by Fluorescence In Situ Hybridization Assay: A 10-Year Experience and Impact of Test Standardization on Concordance Rate.

采用基于计算机图像分析的免疫组化评价HER2/ neu基因状况及其与荧光原位杂交分析基因扩增的相关性:10年的经验和标准化检测对符合率的影响。

Sarode VR,Xiang QD,Christie A,Collins R,Rao R,Leitch AM,Euhus D,Haley B

Abstract

Context .- The American Society of Clinical Oncology/College of American Pathologists proposed several recommendations for human epidermal growth factor receptor 2 (HER2) test standardization. One suggestion was that image analysis (IA) could be useful for scoring of HER2/neu immunohistochemistry. The utilization of IA in a real-world practice in a large cohort of cases has not been previously reported. Objectives .- To compare HER2/neu quantification by IA with gene amplification by fluorescence in situ hybridization (FISH); to determine sensitivity, specificity, and concordance rates with the FISH assay; and to determine association between HER2 status with estrogen receptor (ER), progesterone receptor (PR), and Ki-67 expression. Design .- We evaluated HER2 results performed by immunohistochemistry and FISH in conjunction with ER, PR, and Ki-67 in 3093 invasive breast cancer cases from 2002 to 2011. Results .- The overall concordance between immunohistochemistry and FISH was 87.3% (1768 of 2026). When analyzed by year, there was an improvement in the positive concordance rate from 49.4% (44 of 89) to 95.0% (57 of 60) (P < .001). The negative concordance rate was at least 95% with a median false-negative rate of 1.5%. In the FISH+ group, amplification ratio showed significant correlation with IA scores (P < .001). Positive versus negative HER2 status was associated with lower ER and PR levels (P < .001) and higher Ki-67 expression (P < .001). Conclusion .- Scoring of HER2/neu by IA was associated with high false-positive rates before 2008. Improvement in concordance rate after 2008 may be due to proper tissue handling, improved HER2/neu scoring by IA, and assay standardization.

摘要

摘要:

内容:美国临床肿瘤学会/美国病理学家学会提出了人表皮生长因子受体2(HER2)标准化检测的若干建议。其中一个建议是图像分析(IA)对HER2/neu免疫组化的评分可能很有用。以前并未见在实际工作中对大队列数据使用IA分析的报道。

目的:通过荧光原位杂交(FISH)由IA比较HER2/ neu基因与定量的基因扩增;确定FISH分析的敏感性、特异性和符合率;确定HER2状态与雌激素受体(ER)、孕激素受体(PR)和Ki-67表达的相关性。

设计:选取2002-2011年的3093例浸润性乳腺癌为研究对象,应用免疫组化和FISH评估HER-2结果,并联合分析ER、PR和Ki-67的状态。

结果:免疫组化和FISH 的总一致率是87.3%(1768 /2026)。分析每年的数据,发现阳性一致率从49.4% (44 /89)提高到(57 /60) (P < .001)。阴性一致率至少是95%,平均假阴性率是1.5%。在FISH+组,扩增率和IA得分显著相关(P < .001)。HER2阳性与阴性的状态与较低的ER和PR水平及较高的Ki-67表达水平相关(P < .001)。

结论:在2008年之前,由IA计数的HER2/neu得分与假阳性率高有关。2008年之后一致率的提高可能是由于合适的组织处理﹑IA对HER2/neu评分得以改善、实验的标准化所致。