The positive impact of simultaneous implementation of the BD FocalPoint GS Imaging System and lean principles on the operation of gynecologic cytology.

Wong R,Levi AW,Harigopal M,Schofield K,Chhieng DC

Abstract

Our cytology laboratory, like many others, is under pressure to improve quality and provide test results faster while decreasing costs. We sought to address these issues by introducing new technology and lean principles.
To determine the combined impact of the FocalPoint Guided Screener (GS) Imaging System (BD Diagnostics-TriPath, Burlington, North Carolina) and lean manufacturing principles on the turnaround time (TAT) and productivity of the gynecologic cytology operation.
We established a baseline measure of the TAT for Papanicolaou tests. We then compared that to the performance after implementing the FocalPoint GS Imaging System and lean principles. The latter included value-stream mapping, workflow modification, and a first in-first out policy.
The mean (SD) TAT for Papanicolaou tests before and after the implementation of FocalPoint GS Imaging System and lean principles was 4.38 (1.28) days and 3.20 (1.32) days, respectively. This represented a 27% improvement in the average TAT, which was statistically significant (P < .001). In addition, the productivity of staff improved 17%, as evidenced by the increase in slides screened from 8.85/h to 10.38/h. The false-negative fraction decreased from 1.4% to 0.9%, representing a 36% improvement.
In our laboratory, the implementation of FocalPoint GS Imaging System in conjunction with lean principles resulted in a significant decrease in the average TAT for Papanicolaou tests and a substantial increase in the productivity of cytotechnologists while maintaining the diagnostic quality of gynecologic cytology.