首页 > 期刊杂志 > 正文

Simple Laboratory Test Utilization Interventions to Reduce Inappropriate Specialty Coagulation Testing.

Huang H,Cunningham AM,Harrington AM

Abstract

The naming convention in coagulation may cause confusion in electronic ordering systems, leading to inappropriate test orders. We implemented test utilization efforts and studied utilization before and after interventions for two specialty coagulation assays.
Two interventions were implemented: test names were changed from factor assay to activity, and residents reviewed all factor V and X requests. A retrospective review of factor V and X activity orders was performed for the period 1 year before and after interventions.
After interventions, factor V and X activity orders decreased by approximately 40%. Resulted tests decreased by 53.8% and 47.8%, corresponding to reductions of $2,493.05 and $1,867.80 per year in laboratory charges for factor V and factor X activity, respectively. Abnormal factor V activity results increased from 45% to 59%. Factor V activity orders from outpatient clinics decreased by 21.6%.
Simple interventions can reduce inappropriate specialty coagulation test orders and unnecessary costs.

摘要

full text

我要评论

0条评论