首页 > 期刊杂志 > 正文

Utilization of Cell-Transfer Technique for Molecular Testing on Hematoxylin-Eosin-Stained Sections: A Viable Option for Small Biopsies That Lack Tumor Tissues in Paraffin Block.

Wu HH,Jovonovich SM,Randolph M,Post KM,Sen JD,Curless K,Cheng L

Abstract

- In some instances the standard method of doing molecular testing from formalin-fixed, paraffin-embedded block is not possible because of limited tissue. Tumor cell-enriched cell-transfer technique has been proven useful for performing immunocytochemistry and molecular testing on cytologic smears.
- To establish the cell-transfer technique as a viable option for isolating tumor cells from hematoxylin-eosin (H&E)-stained slides.
- Molecular testing was performed by using the cell-transfer technique on 97 archived H&E-stained slides from a variety of different tumors. Results were compared to the conventional method of molecular testing.
- Polymerase chain reaction-based molecular testing via the cell-transfer technique was successfully performed on 82 of 97 samples (85%). This included 39 of 47 cases for EGFR, 10 of 11 cases for BRAF, and 33 of 39 cases for KRAS mutations. Eighty-one of 82 cell-transfer technique samples (99%) showed agreement with previous standard method results, including 4 mutations and 35 wild-type alleles for EGFR, 4 mutations and 6 wild-type alleles for BRAF, and 11 mutations and 21 wild-type alleles for KRAS. There was only 1 discrepancy: a cell-transfer technique with a false-negative >KRAS result (wild type versus G12C).
- Molecular testing performed on H&E-stained sections via cell-transfer technique is useful when tissue from cell blocks and small surgical biopsy samples is exhausted and the only available material for testing is on H&E-stained slides.

摘要

full text

我要评论

0条评论