Abstract
Most preanalytical errors at our institution occur during nonphlebotomy blood draws. We implemented an electronic health record (EHR), interfaced the EHR to the laboratory information system, and designed a new specimen collection module. We studied the effects of the new system on nonphlebotomy preanalytical errors.
We used an electronic database of preanalytical errors and calculated the number and type of the most common errors in the emergency department (ED) and inpatient nursing for 3-month periods before (August-October 2014) and after (August-October 2015) implementation. The level of staff compliance with the new system was also assessed.
The average monthly preanalytical errors decreased significantly from 7.95 to 1.45 per 1,000 specimens in the ED (P < 0001) and 11.75 to 3.25 per 1,000 specimens in inpatient nursing (P < 0001). The rate of decrease was similar for mislabeled, unlabeled, wrong specimen received and no specimen received errors. Most residual errors (80% in the ED and 67% in inpatient nursing) occurred when providers did not use the new system as designed.
Implementation of a customized specimen collection module led to a significant reduction in preanalytical errors. Improved compliance with the system may lead to further reductions in error rates.
共0条评论