Effectiveness of multiple initiatives to reduce blood component wastage.

多个减少血液成分损耗举措的效果

Collins RA,Wisniewski MK,Waters JH,Triulzi DJ,Yazer MH

Abstract

Blood component waste is an important issue at all hospitals. As an initiative of the patient blood management program at a regional health care system, the causes and extent of blood product wastage were identified, and targeted interventions to effect a reduction were implemented.
Multiple low-cost interventions, including educational outreach, print and digital messaging, and improved transportation and component identification modalities, were implemented beginning in January 2013. The impact on reducing RBC, platelet (PLT), and plasma wastage in the 16 months after intervention implementation was compared with the wastage rates in the 16 months before these interventions had been implemented.
Overall, the RBC wastage rate as a percentage of the number of units issued decreased from 0.67% to 0.56% (P = .001) after the interventions were implemented, while the PLT wastage rate decreased from 3.71% to 2.81% (P < .001). The plasma wastage rate increased from 1.14% to 1.40% (P < .001). The initial cost of these interventions was approximately $310. The net cost savings of the reduced waste was estimated at $131,520, excluding intervention costs.
Relatively inexpensive interventions can have a prompt and dramatic impact on reducing blood wastage with regard to both cost and resource savings.

摘要

血液成分损耗在所有的医院都是一个重要的问题。作为区域保健系统中患者血液管理程序之一,需确定血液产品损耗的原因和程度,并实施减少损耗为目的的干预措施。

从2013年1月开始实施多项低成本干预措施,包括宣传教育、印刷品和数字通讯,改善传输以及成分输血法。在干预措施实施后的16个月里,对红细胞、血小板和血浆消耗与实施前进行对比。

总的来说,每个单位的红细胞损耗率在干预措施实施后从0.67%降至0.56%(P=.001),而血小板损耗率从3.71%降至2.81%(P < .001)。血浆损耗率从1.14%升高至1.40%(P < .001)。这些干预措施的初级成本约$310。损耗降低的净成本节约$131,520,不包括干预的成本。

相对便宜的干预措施在成本和资源节约方面,可以对血液损耗产生立竿见影的影响。