Few reports have documented the effectiveness of Lean quality improvement in changing anatomic pathology patient safety. We used Lean methods of education; hoshin kanri goal setting and culture change; kaizen events; observation of work activities, hand-offs, and pathways; A3-problem solving, metric development, and measurement; and frontline work redesign in the accessioning and gross examination areas of an anatomic pathology laboratory. We compared the pre- and post-Lean implementation proportion of near-miss events and changes made in specific work processes. In the implementation phase, we documented 29 individual A3-root cause analyses. The pre- and postimplementation proportions of process- and operator-dependent near-miss events were 5.5 and 1.8 (P < .002) and 0.6 and 0.6, respectively. We conclude that through culture change and implementation of specific work process changes, Lean implementation may improve pathology patient safety.